HTC01 : Hot Runner Controller
Features :
- Precision temperature control
High quality heat sink plate prevents triac damage due to heat
Precise current monitoring
Thermocouple failure indication (Open & Reverse), auto terminate output
Heater failure indication ( Short Circuit, Open & Over current), auto terminate output
Triac, Fuse broken indication
Alarm LED indication and Buzzer
Misconnection between T/c and Heater protection
380V overload protection
Stackable design to saves installation space.
Handle in front to remove easily.
Built in NFB switch
Parameter protection function
Universal standardized chassis for any brand of module
Casing Specifications |
||||||
HTC01 | 1 zone | 2 zones | 4 zones | 6 zones | 8 zones | 12 zones |
Type | PNL-HR-1 | PNL-HR-2 | PNL-HR-4 | PNL-HR-6 | PNL-HR-8 | PNL-HR-12 |
Power Switch Capacity(A) | None | 32-2P | 32-3P | 32-3P | 63-3P | 63-3P |
Output Connector | 4pin+E(ground) | 16pins x1 | 16pins x1 | 24pins x1 | 16pins x2 | 24pins x2 |
Power Cable | 2.5mm²x 3C x 3M | 2.5mm² x 3C x 3M | 6mm² x 5C x 3M | 6mm² x 5C x 3M | 10mm² x 5C x 3M | 10mm² x 5C x 3M |
Dimension W x H x D (mm) | 96 x 188 x 278 | 223 x 215 x 344 | 323 x 215 x 344 | 424 x 215 x 344 | 524 x 215 x 344 | 726 x 215 x 344 |
Module Specifications | |
Specification | HTC01 |
Control Points | 1 zone |
Power Input | 85~265Vac, 50/60Hz |
Power Consumption | 3W |
Power Output | 3500W,230VAC/15A |
Output Mode | Phase angel |
Input Temp. Sensor | J/K type |
Temp. Unit | °C/°F |
Temp. Control Range | 45~550°C/ 110~999°F |
Alarm Indication & Buzzer | Yes |
Control Accuracy | ±0.5% FS |
Measurement Accuracy | ±1% FS |
Repeat Measure Accuracy | ±0.1% FS) |
Storage Temp | -40~70°C/-40~158°F |
Working Temp | 0~55°C/32~131°F |
Humidity | 10~95%RH.(non-condensing) |
Fuse | Fast response ceramic F20A 250V 6.3*32 |
Current Detection Function | Yes |
Communication Mode | Optional |