HTC01 : Hot Runner Controller

Features :

  • Precision temperature control
    High quality heat sink plate prevents triac damage due to heat
    Precise current monitoring
    Thermocouple failure indication (Open & Reverse), auto terminate output
    Heater failure indication ( Short Circuit, Open & Over current), auto terminate output
    Triac, Fuse broken indication
    Alarm LED indication and Buzzer
    Misconnection between T/c and Heater protection
    380V overload protection
    Stackable design to saves installation space.
    Handle in front to remove easily.
    Built in NFB switch
    Parameter protection function
    Universal standardized chassis for any brand of module

Casing Specifications

HTC01 1 zone 2 zones 4 zones 6 zones 8 zones 12 zones
Type PNL-HR-1 PNL-HR-2 PNL-HR-4 PNL-HR-6 PNL-HR-8 PNL-HR-12
Power Switch Capacity(A) None 32-2P 32-3P 32-3P 63-3P 63-3P
Output Connector 4pin+E(ground) 16pins x1 16pins x1 24pins x1 16pins x2 24pins x2
Power Cable 2.5mm²x 3C x 3M 2.5mm² x 3C x 3M 6mm² x 5C x 3M 6mm² x 5C x 3M 10mm² x 5C x 3M 10mm² x 5C x 3M
Dimension W x H x D (mm) 96 x 188 x 278 223 x 215 x 344 323 x 215 x 344 424 x 215 x 344 524 x 215 x 344 726 x 215 x 344
Module Specifications
Specification HTC01
Control Points 1 zone
Power Input 85~265Vac, 50/60Hz
Power Consumption 3W
Power Output 3500W,230VAC/15A
Output Mode Phase angel
Input Temp. Sensor J/K type
Temp. Unit °C/°F
Temp. Control Range 45~550°C/ 110~999°F
Alarm Indication & Buzzer Yes
Control Accuracy ±0.5% FS
Measurement Accuracy ±1% FS
Repeat Measure Accuracy ±0.1% FS)
Storage Temp -40~70°C/-40~158°F
Working Temp 0~55°C/32~131°F
Humidity 10~95%RH.(non-condensing)
Fuse Fast response ceramic F20A 250V 6.3*32
Current Detection Function Yes
Communication Mode Optional