HTC N1 : Hot Runner Controller
Features :
- Precision temperature control
- High quality heat sink plate prevents triac damage due to heat
- Precise current monitoring
- Thermocouple failure indication (Open & Reverse), auto terminate output
- Heater failure indication ( Short Circuit, Open & Over current), auto terminate output
- Triac, Fuse broken indication
- Alarm LED indication and Buzzer
- Misconnection between T/c and Heater protection
- 380V overload protection
- Stackable design to saves installation space.
- Handle in front to remove easily.
- Built in NFB switch
- Parameter protection function
- Universal standardized chassis for any brand of module
Casing Specifications |
||||||
HTC N1 | 1 zone | 2 zones | 4 zones | 6 zones | 8 zones | 12 zones |
Type | PNL-HR-1 | PNL-HR-2 | PNL-HR-4 | PNL-HR-6 | PNL-HR-8 | PNL-HR-12 |
Power Switch Capacity(A) | None | 32-2P | 32-3P | 32-3P | 63-3P | 63-3P |
Output Connector | 4pin+E(ground) | 16pins x1 | 16pins x1 | 24pins x1 | 16pins x2 | 24pins x2 |
Power Cable | 2.5mm²x 3C x 3M | 2.5mm² x 3C x 3M | 6mm² x 5C x 3M | 6mm² x 5C x 3M | 10mm² x 5C x 3M | 10mm² x 5C x 3M |
Dimension W x H x D (mm) | 96 x 188 x 278 | 223 x 215 x 344 | 323 x 215 x 344 | 424 x 215 x 344 | 524 x 215 x 344 | 726 x 215 x 344 |
Module Specifications | |
Specification | HTC N1 |
Control Points | 1 zone |
Power Input | 85~265Vac, 50/60Hz |
Power Consumption | 3W |
Power Output | 3500W,230VAC/15A |
Output Mode | Phase angel |
Input Temp. Sensor | J/K type |
Temp. Unit | °C/°F |
Temp. Control Range | 45~550°C/ 110~999°F |
Alarm Indication & Buzzer | Yes |
Control Accuracy | ±0.5% FS |
Measurement Accuracy | ±1% FS |
Repeat Measure Accuracy | ±0.1% FS) |
Storage Temp | -40~70°C/-40~158°F |
Working Temp | 0~55°C/32~131°F |
Humidity | 10~95%RH.(non-condensing) |
Fuse | Fast response ceramic F20A 250V 6.3*32 |
Current Detection Function | Yes |
Communication Mode | Optional |