HTC N1 : Hot Runner Controller

Features :

  • Precision temperature control
  • High quality heat sink plate prevents triac damage due to heat
  • Precise current monitoring
  • Thermocouple failure indication (Open & Reverse), auto terminate output
  • Heater failure indication ( Short Circuit, Open & Over current), auto terminate output
  • Triac, Fuse broken indication
  • Alarm LED indication and Buzzer
  • Misconnection between T/c and Heater protection
  • 380V overload protection
  • Stackable design to saves installation space.
  • Handle in front to remove easily.
  • Built in NFB switch
  • Parameter protection function
  • Universal standardized chassis for any brand of module

Casing Specifications

HTC N1 1 zone 2 zones 4 zones 6 zones 8 zones 12 zones
Type PNL-HR-1 PNL-HR-2 PNL-HR-4 PNL-HR-6 PNL-HR-8 PNL-HR-12
Power Switch Capacity(A) None 32-2P 32-3P 32-3P 63-3P 63-3P
Output Connector 4pin+E(ground) 16pins x1 16pins x1 24pins x1 16pins x2 24pins x2
Power Cable 2.5mm²x 3C x 3M 2.5mm² x 3C x 3M 6mm² x 5C x 3M 6mm² x 5C x 3M 10mm² x 5C x 3M 10mm² x 5C x 3M
Dimension W x H x D (mm) 96 x 188 x 278 223 x 215 x 344 323 x 215 x 344 424 x 215 x 344 524 x 215 x 344 726 x 215 x 344
Module Specifications
Specification HTC N1
Control Points 1 zone
Power Input 85~265Vac, 50/60Hz
Power Consumption 3W
Power Output 3500W,230VAC/15A
Output Mode Phase angel
Input Temp. Sensor J/K type
Temp. Unit °C/°F
Temp. Control Range 45~550°C/ 110~999°F
Alarm Indication & Buzzer Yes
Control Accuracy ±0.5% FS
Measurement Accuracy ±1% FS
Repeat Measure Accuracy ±0.1% FS)
Storage Temp -40~70°C/-40~158°F
Working Temp 0~55°C/32~131°F
Humidity 10~95%RH.(non-condensing)
Fuse Fast response ceramic F20A 250V 6.3*32
Current Detection Function Yes
Communication Mode Optional